Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiology ; (12): 650-654, 2021.
Article in Chinese | WPRIM | ID: wpr-884461

ABSTRACT

Objective:To investigate the accuracy of 3.0 T MR in the diagnosis of full thickness tear and partial thickness tear of the supraspinatus-infraspinatus tendon, and to analyze the causes of missed diagnosis and misdiagnosis of the supraspinatus-infraspinatus tendon tear.Methods:The MRI diagnosis report and arthroscopic surgery records of 210 patients with shoulder joint injuries in Peking University Third Hospital were analyzed retrospectively. Taking the results of arthroscopic surgery as the gold standard, the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive values of 3.0 T MR for full thickness tear and partial thickness tear of the supraspinatus-infraspinatus tendon were calculated, and the reasons of missed diagnosis and misdiagnosis were analyzed.Results:In 210 patients with rotator cuff injury, the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of MRI for full thickness tear of the supraspinatus-infraspinatus tendon were 81.4% (171/210), 83.1% (98/118), 79.3% (73/92), 83.7% (98/117) and 78.4% (73/93) respectively. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of MRI for partial tears of the supraspinatus-infraspinatus tendons were 77.6% (163/210), 65.7% (44/67), 83.2% (119/143), 64.7% (44/68) and 83.8% (119/142) respectively. Among the 44 cases of missed diagnosis and misdiagnosis of the supraspinatus-infraspinatus tendon tear, 21 cases (47.7%) occurred in the junction supraspinatus and infraspinatus tendon-osseous (stop). Among the 7 cases of intra-tendon tear of supraspinatus and infraspinatus muscle, 6 cases were misdiagnosed cases, which was the most easily missed diagnosed type of partial tear. The reason for missed diagnosis was that the signal of partial tear was not high (no fluid signal was shown on T 2WI). Complex laceration was also a type of missed diagnosis in partial tears. Among the 4 cases of superior and inferior surface tendons combined with intra-tendon lacerations, 3 cases were missed diagnosed. Conclusion:3.0 T MR has higher accuracy for the diagnosis of full thickness tear and partial thickness tear of supraspinatus-infraspinatus tendon, but there is still a certain rate of misdiagnosis and missed diagnosis. A full understanding of the causes of misdiagnosis and missed diagnosis of MR in the diagnosis of rotator cuff tears of supraspinatus and infraspinatus tendons is helpful to further improve the accuracy of MR in the diagnosis of supraspinatus and infraspinatus tendon injuries of shoulder joint.

2.
Chinese Journal of Blood Transfusion ; (12): 878-882, 2021.
Article in Chinese | WPRIM | ID: wpr-1004435

ABSTRACT

【Objective】 To analyze the cause of single-ELISA reactive of four blood screening items in 18 blood stations in Henan, so as to provide the basis for improving the quality of blood screening. 【Methods】 The single-ELISA reactive rate of HBsAg, anti-HCV, HIV Ag/Ab and anti-TP of 18 blood station laboratories in Henan throughout 2019 was calculated, and the causes were analyzed according to different ELISA reagent combinations and gray area settings in each laboratory. 【Results】 The overall single-ELISA reactive rates of HBsAg, anti-HCV, HIV Ag/Ab and anti-TP were 1.740(2 154/1 237 789), 0.564‰(698/1 237 789), 1.421‰(1 759/1 237 789) and 1.561‰(1 932/1 237 789), respectively, showing significant differences by detection items (P <0.05). Person correlation analysis showed that the single-ELISA reactive rate was independent of the gray area settings.but dependent on laboratories and reagent combinations. The single-ELISA reactive rate of HBsAg, anti-HCV, HIV Ag/Ab and anti-TP in D laboratory was the highest and higher than that in other labs using the same reagent.The laboratories with high HBsAg single-ELISA reactive rate were mostly those using a combination of imported reagents and domestic reagents, including the top 6 laboratories. The laboratories with high anti-HCV single-ELISA reactive rate were mostly those using certain domestic reagents. No obvious rules was noticed by single-ELISA reactive for anti-HIV. Laboratories with high anti-TP single-ELISA reactive rate were mostly those using combination 4. 【Conclusion】 The HBsAg single-ELISA reactive rate was the highest in the four blood screening items of blood station laboratories in Henan. The single-ELISA reactive rate is related to the laboratory itself and the reagent manufacturer, suggesting that laboratory quality control should be strengthened and proper reagent combination should be selected to reduce the waste of blood.

3.
Chinese Journal of Blood Transfusion ; (12): 68-72, 2021.
Article in Chinese | WPRIM | ID: wpr-1003928

ABSTRACT

【Objective】 To analyze the HIV-, HCV- and HBV- NAT yield rate in different areas of Henan province, so as to provide the basis for disease prevention and control as well as the establishment of a unified quality control standard for nucleic acid testing(NAT) in the Henan province. 【Methods】 The number and prevalence of NAT yielding samples with isolated infectious virus, namely HIV, HCV and HBV, in 18 blood stations in Henan province from 2017~2019, as well as the trends were analyzed. The NAT quality of each laboratory and each testing system was analyzed according to the ratio of reactive individual donation(ID) results to reactive minipools(MP). 【Results】 The HBV, HCV and HIV ID-NAT yield numbers in 3 501 251 blood donations were HBV 2 606(74/100 000), HCV 21 (0.63/100 000), and HIV 34(1.00/100 000). The HBV ID-NAT yield rate showed an upward trend in the whole province from 2017 to 2019, while the prevalence of HIV and HCV ID-NAT yield didn′t differ significantly during three years. 5 kinds of NAT detection systems were applied in 18 blood centers. among which Ⅰ, Ⅱ, Ⅳ and Ⅴ were triplex detection systems. 2661 ID-reactive samples were implicated in 5 595 MP-reactive samples, with a resolution rate of 47.56%. The resolution rate of triplex NAT system Ⅰ, Ⅱ, Ⅳ and Ⅳ was 39.63%~47.95%, 40.43%~54.36%, 51.61% and 70.00%~45.45%, respectively. An upward trend in triplex NAT resolution rate was observed in 8 laboratories, i. e.B, D, E, F, I, K, L and Q, and an descending trend in A and C. The NAT system Ⅲ, a ID-NAT system, was used only by laboratory C, presenting a NAT-yield rate of 0.19% (282/145 474) and resolution rate of 46.45% (131/282). 【Conclusion】 The majority of NAT-yield of one infectious virus in Henan province is HBV, presenting annual increasing trend. The quality management of NAT laboratories should be strengthened as the divergence was seen in the performance of different NAT laboratories.

4.
Chinese Journal of Medical Genetics ; (6): 683-685, 2018.
Article in Chinese | WPRIM | ID: wpr-688168

ABSTRACT

<p><b>OBJECTIVE</b>To detect potential mutation of TCOF1 gene in a Chinese family affected with Treacher-Collins syndrome.</p><p><b>METHODS</b>Clinical data of the patient was collected. The analysis included history taking, clinical examination and genetic testing. All coding regions of the TCOF1 gene were subjected to PCR amplification and Sanger sequencing.</p><p><b>RESULTS</b>A novel mutation c.2261ins G (p.E95X) of the TCOF1 gene was discovered in the patient. The same mutation was not found in his parents and 100 healthy controls.</p><p><b>CONCLUSION</b>The c.2261insG (p.E95X) mutation of the TCOF1 gene probably underlies the disease in the patient. Genetic testing can facilitate diagnosis and genetic counseling for families affected with TCS.</p>

5.
Chinese Journal of Practical Nursing ; (36): 619-622, 2016.
Article in Chinese | WPRIM | ID: wpr-672369

ABSTRACT

Objective To explore the influences of health belief model education on training of international classifiction of functioning,disability and health (ICF) generic set in nurses.Methods Eighty-four nurses from 28 hospitals received a set of education of ICF generic set based on health belief model.Nurses' knowledge and belief of ICF generic set were evaluated before and after education.Results The score of ICF generic set knowledge after education was (5.63±0.75) points,which was higher than that of before education 1 (2) points,and there was significant difference (Z=10.092,P< 0.05).The scores of ICF generic set belief and perceived susceptibility and perceived barriers dimensions were (63.01±7.04),(11.21±1.45),(13.87±2.68) points after education,and (59.62±6.25),(10.11±3.07),(12.68±3.63) points before education,and there were significant differences(t=3.301,2.986,2.414,P< 0.05).Conclusions The heath belief model education can improve the ICF generic set knowledge level of nurses,enhance the nurses' confidence and lower the possible perceived barriers in the application of ICF generic set,and thereby can improve the ICF generic set belief level of nurses.

6.
Chinese Journal of Practical Nursing ; (36): 1209-1211, 2015.
Article in Chinese | WPRIM | ID: wpr-470160

ABSTRACT

Objective To survey the female sexual status and its influence factors during the second trimester of pregnancy.Methods The Chinese Version of Female Sexual Function Index (FSFI) and self-administered questionnaires were used to collect the data of 304 women during the second trimester of pregnancy.The investigation results were analyzed.Results Most women reported a decrease in sexual desire(74.7%,227/304),intercourse frequency(90.8%,276/304) and sexual satisfaction(41.1%,125/304).FSFI all dimensions mean scores of these 304 women during the second trimester of pregnancy were less than the critical value,and total FSFI was (20.82±3.74) scores.The female sexual status during the second trimester of pregnancy were affected by age,duration of marriage,education,the way of pregnancy,F=21.974,12.288,3.345,7.748,the differences were statistically significant,P<0.05.Conclusion Pregnant women are in a low level sexual function during the relative safety stage for sexual behavior during the second trimester of pregnancy,so providing some sexual education is necessary to improve couples' sexual health.

7.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 1348-1351, 2015.
Article in Chinese | WPRIM | ID: wpr-480624

ABSTRACT

@#Objective To investigate the knowledge, belief and practice regarding ICF Generic Set in nurses. Methods 107 nurses from 28 secondary- and tertiary-level hospitals were investigated with self-administered questionnaires. Results In the knowledge dimension, 16.3%~39.4% of the nurses were accurate in each item respectively. The nurses got a middle grade in the attitude dimension and all the sub-dimensions. In terms of practice, 39.4%of hospitals and 44.2%of nurses had never used ICF, and the personal usage of ICF correlated with the scores of the knowledge and perceived susceptibility, perceived benefits, perceived barriers and perceived threat of belief. Conclu-sion The nurses are inadequate in the knowledge and attitude of ICF, and the application of ICF need more promotion.

SELECTION OF CITATIONS
SEARCH DETAIL